A large number of nozzles are clogged simultaneously, but they are improved after cleaning once. However, nozzles are clogged again after a while

Suspected cause
  • There are bubbles in the ink path.

  • Foreign matter builds up in the Self Sealing Valve Filter of the ON-CR Unit. (Is forced output by the strong CL. But is not forced output by weak FL.)

Parts/Components to be checked
  1. Print Head
  2. Self Sealing Valve Assy
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Perform head cleaning (CL3) again

Does the product recover from nozzle clogging?

CleaningEndGo to step 2
2

Perform the initial charge.

Does the product recover from nozzle clogging?

Initial Ink ChargeEndGo to step 3
3

Wiping the Print Head

Does the product recover from nozzle clogging?

Wiping the Print HeadEndGo to step 4
4

Replace the Self Sealing Valve Assy

Does the product recover from the failure?

Self Sealing Valve AssyEndEscalate to person in charge