00141C (Pump Cap Unit Reversing Error)
Error contents
- The number of occurrences of reversing the Pump Motor has reached a predetermined limit.
Suspected cause
- Pump Motor Encoder cable abnormality (polarity reversal)
- Pump Motor cable abnormality (polarity reversal)
Parts/Components to be checked
- Pump Cap unit
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 2 | |
2 | Check the Pump Cap Unit operation state.
Does the product recover from the error? | Pump Cap unit | End | Escalate to person in charge |