001114 (Sub Board Startup Error)

Error contents
  • CH83 Main-B Circuit Board failed to start.
Suspected cause
  • Secure boot failed to boot on the CH83 Main-B Circuit Board.
Parts/Components to be checked
  1. Firmware
  2. CH83 Main-B Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Turn power OFF/ON.

Does the product recover from the error?

---EndGo to step 2
2

Reinstall the firmware in Program Update Mode. Even if an error occurs, FW installation is possible, so install it.

Does the product recover from the error?

Modes for Service

Firmware Install

EndGo to step 3
3

Replace the CH83 Main-B Circuit Board.
Does the product recover from the error?