00122C (PF Driven Roller Motor Reversing Error)
Error contents
- The number of occurrences of reversing the PF Driven Roller Motor has reached a predetermined limit.
Suspected cause
- PF Driven Roller Motor Encoder cable abnormality (polarity reversal)
- PF Driven Roller Motor cable abnormality (polarity reversal)
- Slipping of the teeth of the PF Driven Roller Belt
- PF Driven Roller Motor Encoder failure
Parts/Components to be checked
- PF Belt
- PF Encoder
- PF Driven Roller Motor
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the PF Belt state.
Does the product recover from the error? | End | Go to step 2 | |
2 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 3 | |
3 | Replace the PF Encoder. Does the product recover from the error? | PF Encoder | End | Go to step 4 |
4 | Replace the PF Driven Roller Motor. Does the product recover from the error? | PF Driven Roller Motor | End | Escalate to person in charge |