00151F (APG Motor Lock Error)

Error contents
  • The APG Motor was driven at a speed abnormally slower than a predetermined one during operation.
  • The waveform is not detected when the APG Motor is driving.
Suspected cause
  • APG Motor Encoder cable abnormality (connection, broken)
  • APG Motor cable abnormality (connection, broken)
  • Abnormal load
  • APG Motor Encoder failure
  • APG Motor failure
Parts/Components to be checked
  1. APG Unit
  2. Printer Main Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the cable connection of the APG Motor Encoder

  • Check the connection status of the APG Motor Encoder, and, if abnormal, reconnect.

Does the product recover from the error?

EndGo to step 2
2

Replace the APG Unit.

Does the product recover from the error?

APG UnitEndEscalate to person in charge