00130A (ASF Motor Overload Error)
Error contents
- Overcurrent to the ASF Motor was detected.
- The ASF Motor rotation speed is not attained or is not detected correctly.
Suspected cause
- Abnormal load
- ASF Motor Encoder cable abnormality (connection, broken)
- ASF Motor cable abnormality (connection, broken)
- ASF Motor Encoder failure
- ASF Motor failure
- Printer Main Circuit Board failure
Parts/Components to be checked
- ASF Motor
Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the obstacle in the PF operation range
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the cable connection of the ASF Motor Encoder
Does the product recover from the error? | ASF Motor | End | Go to step 3 |
3 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 4 | |
4 | Is there a foreign object in the driving section of the ASF Motor? Does the product recover from the error? | ASF Motor | End | Go to step 5 |
5 | Replace the ASF Motor. Does the product recover from the error? | ASF Motor | End | Go to step 6 |
6 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |