001229 (PF Driven Roller Motor Oscillation Error)
Error contents
- The number of oscillations exceeds the specified value.
- The control terminal (Vre terminal) of the PF Driven Roller Motor Driver was short-circuited.
Suspected cause
- CH83 Main-B Circuit Board failure
- PF Driven Roller Motor failure
Parts/Components to be checked
- CH83 Main-B Circuit Board
- PF Driven Roller Motor
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the status of the CH83 Main-B Circuit Board
Does the product recover from the error? | CH83 Main-B Circuit Board | End | Go to step 2 |
2 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Go to step 3 |
3 | Replace the PF Driven Roller Motor. Does the product recover from the error? | PF Driven Roller Motor | End | Escalate to person in charge |