001A46 (HCS Communication Error Head)
Error contents
- HCS3 communications failed between CH83 Main-B Circuit Board and CH83 DRV-H Board and the head (somewhere on path between head side, CH83 Main-B Circuit Board, and CH83 DRV-H Board).
- Error from external sources such as noise, etc.
Suspected cause
- Head Board signal short-circuit, broken lead
- Head FFC abnormality (skewed connection/broken lead/short-circuit)
- CH83 DRV-H Board signal short-circuit, broken lead
- CH83 Main-B Circuit Board signal short-circuit, broken lead
Parts/Components to be checked
- Head FFC Assy
- Print Head
- CH83 DRV-H Board
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Turn power OFF/ON Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the Head FFC connection state
Does the product recover from the error? | Head FFC Assy | End | Go to step 3 |
3 | Replace the Print Head Does the product recover from the error? | Print Head | End | Go to step 4 |
4 | Replace the CH83 DRV-H Board Does the product recover from the error? | CH83 DRV-H Board | End | Go to step 5 |
5 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |