Part or all of an image cannot be read.
Suspected cause
- Contamination on the White Base Assy
- Contamination on the document feed path
- Connection failure of the CIS Module
- Problem in the connection between the printer and the scanner
- CIS Module failure
- Scanner Main Board failure
Parts/Components to be checked
- CIS Module
Scanner Main Board
White Base Assy
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Carry out cleaning
Does the product recover from the failure? | --- | End | Go to step 2 |
2 | Check the CIS Module related FFC routing
Does the product recover from the failure? | --- | End | Go to step 3 |
3 | Check the connection between the printer and the scanner
Does the product recover from the failure? | --- | End | Go to step 4 |
4 | Replace the CIS Module Does the product recover from the failure? | End | Go to step 5 | |
5 | Replace the Scanner Main Board Does the product recover from the failure? | Scanner Main Board | End | Escalate to person in charge |