0016CC (Shutter Motor Driving time-out Error)
Error contents
- The number of occurrences of reversing the Shutter Motor has reached a predetermined limit.
Suspected cause
- Shutter Motor Encoder cable abnormality (polarity reversal)
- Shutter Motor cable abnormality (polarity reversal)
- Slipping of the teeth of the Shutter Motor Gears
- Shutter Motor Encoder failure
Parts/Components to be checked
- Shutter Motor Unit
- Shutter Motor Gears
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the cable connection of the Shutter Motor Unit
Does the product recover from the error? | End | Go to step 2 | |
2 | Replace the shutter Motor Unit. Does the product recover from the error? | Shutter Motor Unit | End | Go to step 3 |
3 | Replace the Shutter Motor Gears. Does the product recover from the error? | Shutter Motor Gears | End | Escalate to person in charge |