The color of head 1 or head 2 comes out completely as shown in the picture.

Suspected cause
  • The Head FFC is abnormal.

Parts/Components to be checked
  1. Head FFC Assy
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the Head FFC Assy connection

  • Check the connection status of the following connection points for foreign material, and then reconnect.
    • CH83 DRV-H Board: CN5 CN202

    • Head (B to B connector): CN4, CN4 

Does the product recover from the failure?

Head FFC AssyEndEscalate to person in charge