00112B (PF Driven Home Position Detection Error)
Error contents
- The driven nip home position cannot be detected at the time of initialization.
- The driven nip cannot return or the sensor does not react.
Suspected cause
- The Mechanical Sensor has failed or its position has been shifted.
- Operation failure due to paper jam
- Poor connection of the PF Driven Home Position Sensor
- PF Driven Home Position Sensor failure
- PF Driven Release Motor failure
- Slipping of the teeth of the PF Driven Nip Gears
- PF driven shaft screw is loosen, and a sensor read position abnormality occurs.
- A: Normal read position
- B: Read position when error occurs

<Normal read position>
- A: PF driven home position flag
- B: PF driven shaft
- C: Screw
- D: Sensor
- E: Sensor detection range

<Read position when error occurs>
- A: Error occurs due to moving the flag

Parts/Components to be checked
- PF Release Sensor
- 1st/2nd Release Motor
- ASF sub Gears
Troubleshooting
| Step | Confirmation points and methods | Page | YES | NO |
|---|---|---|---|---|
| 1 | Check around the Driven Nip for paper jams.
Does the product recover from the error? | --- | End | Go to step 2 |
| 2 | Check the cable connection of the PF Driven Sensor
Does the product recover from the error? | End | Go to step 3 | |
| 3 | If shaft screw is loose, tighten it again.
Does the product recover from the error? | --- | End | Go to step 4 |
| 4 | Replace the 1st / 2nd Release Motor Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 5 |
| 5 | Replace the ASF Sub Gears Does the product recover from the error? | ASF sub Gears | End | Escalate to person in charge |
