256225/356225/DBA1 (CH83 Main-B Circuit Board Failure (Overvoltage) Occurred)

Error contents
  • MAIN-B Board failure (Overvoltage) occurred.
Suspected cause
  • The harness is pinched.
  • CH83 Main-B Circuit Board short due to dust
  • CH83 Main-B Circuit Board failure
Parts/Components to be checked
  1. CH83 Main Board - CH83 Main-B Board FFC
  2. CH83 Main-B Board - CH83 DRV-H Board FFC
  3. CH83 Main-B Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the connection status of the cables connected to the CH83 Main-B Circuit Board

  • Check the connection status of the cables connected to the CH83 Main-B Circuit Board (disconnection, skewed connection, inserted halfway, peeled terminal). If an abnormality is found, reconnect it.
  • If there is an abnormality with cables connected to the CH83 Main-B Circuit Board, and the problem is not resolved even after reconnection, then replace the cables connected to the Main-B Board.

Does the product recover from the error?

CH83 Main Board - CH83 Main-B Board FFC

CH83 Main-B Board - CH83 DRV-H Board FFC

CH83 Main-B Circuit Board

EndGo to step 2
2

Replace the CH83 Main-B Circuit Board

Does the product recover from the error?

CH83 Main-B Circuit BoardEndEscalate to person in charge