256225/356225/DBA1 (CH83 Main-B Circuit Board Failure (Overvoltage) Occurred)
Error contents
- MAIN-B Board failure (Overvoltage) occurred.
Suspected cause
- The harness is pinched.
- CH83 Main-B Circuit Board short due to dust
- CH83 Main-B Circuit Board failure
Parts/Components to be checked
- CH83 Main Board - CH83 Main-B Board FFC
- CH83 Main-B Board - CH83 DRV-H Board FFC
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the connection status of the cables connected to the CH83 Main-B Circuit Board
Does the product recover from the error? | CH83 Main Board - CH83 Main-B Board FFC | End | Go to step 2 |
2 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |