00113C (CR Motor Reversing Error)
Error contents
- The number of occurrences of reversing the CR Motor has reached a predetermined limit.
Suspected cause
- CR Encoder cable abnormality (polarity reversal)
- CR Motor cable abnormality (polarity reversal)
- Slipping of the teeth of the CR Belt
- CR Encoder failure
Parts/Components to be checked
- CR Encoder
- CR Motor
- CH83 SUB (PW/IMS) Board
- CH83 Main-B Circuit Board
- CR Unit
Troubleshooting
| Step | Confirmation points and methods | Page | YES | NO |
|---|---|---|---|---|
| 1 | Check the reading state of the CR Encoder using Service Program. If reading (from the Service Program) cannot be performed, re-install the CR Encoder. Does the product recover from the error? | End | Go to step 2 | |
| 2 | Check the cable connection of the CR Motor
Does the product recover from the error? | End | Go to step 3 | |
| 3 | Replace the CR Encoder. Does the product recover from the error? | CR Encoder | End | Go to step 4 |
| 4 | Check the CR Belt state
Does the product recover from the error? | End | Go to step 5 | |
| 5 | Replace the CR Motor. Does the product recover from the error? | CR Motor | End | Escalate to person in charge |