001A47 (HCS Communication Error Main)
Error contents
- In HCS3 communications between the Printer Main Circuit Board and Main-B Board, CH83 Main Circuit Board internal (FFC communications) communications failed.
Suspected cause
- Printer Main Circuit Board signal short-circuit, broken lead
- CH83 Main-B Circuit Board signal short-circuit, broken lead
- FFC abnormality between Printer Main Circuit Board and CH83 Main-B Circuit Board (skewed connection/broken lead/short-circuit)
Parts/Components to be checked
- CH83 Main Board - CH83 Main-B Board FFC
- Printer Main Circuit Board
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Turn power OFF/ON Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the connection status of the Printer Main Circuit Board - CH83 Main-B Board FFC
Does the product recover from the error? | CH83 Main Board - CH83 Main-B Board FFC | End | Go to step 3 |
3 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Go to step 4 |
4 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |