Joins between CIS Modules are misaligned.

Suspected cause
  • Image Stitching Adjustment value is abnormal


Parts/Components to be checked
  1. ---
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Checking the document state

  • Check that there is no curling or wrinkling in the paper.

Does the product recover from the failure?

---EndGo to step 2
2

Change paper set direction

  • Change the paper set direction, and carry out scan/copy again.

Does the product recover from the failure?

---EndGo to step 3
3

Use the optional carrier sheet

  • Use the optional carrier sheet, and carry out scan/copy again.

Does the product recover from the failure?

---EndGo to step 4
4

Execute the CIS Modules Position & Document Feed Adjustment

Does the product recover from the failure?

CIS Modules Position & Document Feed Adjustment
Go to step 5

5

Execute the Document Feed Adjustment

  • From the printer panel, perform Paper Feed Adjust.

Does the product recover from the failure?

---EndEscalate to person in charge