0016C9 (Shutter Motor Oscillation Error)
Error contents
- The number of oscillations exceeds the specified value.
- The control terminal (Vre terminal) of the Shutter Motor Driver was short-circuited.
Suspected cause
- CH83 Main-B Circuit Board failure
- Shutter Motor failure
Parts/Components to be checked
- CH83 Main-B Circuit Board
- Shutter Motor Unit
- Shutter Motor Gears
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the status of the CH83 Main-B Circuit Board
Does the product recover from the error? | CH83 Main-B Circuit Board | End | Go to step 2 |
2 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Go to step 3 |
3 | Replace the Shutter Motor Unit Does the product recover from the error? | Shutter Motor Unit | End | Go to step 4 |
4 | Replace the Shutter Motor Gears. Does the product recover from the error? | Shutter Motor Gears | End | Escalate to person in charge |