0014C4 (Ink System Maintenance Unit Position Correction Value Error (ISX_ADJ))

Error contents
  • Position correction of the Maintenance Unit cannot be performed correctly. This occurs when the printer does to read the data of the NVRAM and the data deviates outside the threshold range.
Suspected cause
  • The correction values after installation of the Maintenance Unit in process and during servicing were entered incorrectly. In cases where correction values are not adjusted, this error is not output but occurs when correction values are outside threshold values after adjustment.
Parts/Components to be checked
  1. Pump Cap unit
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Adjust the ISX position from the Service Program.

  • Run ISX offset after entering the offset values.

Does the product recover from the error?

Input Offset ValueEndGo to step 2
2

Reinstall the Pump Cap Unit, and adjust the ISX position from the Service Program.

  • Run ISX offset after entering the offset values.

Does the product recover from the error?

Pump Cap unit

Input Offset Value

EndEscalate to person in charge