0012CA (1st / 2nd Release Motor Overload Error)
Error contents
- Overcurrent to the 1st / 2nd Release Motor was detected.
- The 1st / 2nd Release Motor rotation speed is not attained or is not detected correctly.
Suspected cause
- Abnormal load
- 1st / 2nd Release Motor Encoder cable abnormality (connection, broken)
- 1st / 2nd Release Motor cable abnormality (connection, broken)
- 1st / 2nd Release Motor Encoder failure
- 1st / 2nd Release Motor failure
- CH83 Main-B Circuit Board failure
Parts/Components to be checked
- 1st/2nd Release Motor
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the obstacle in the PF operation range
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the 1st / 2nd Release Motor Encoder cable connection
Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 3 |
3 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 4 | |
4 | Check the driving section of the 1st / 2nd Release Motor for foreign objects. Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 5 |
5 | Replace the 1st / 2nd Release Motor. Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 6 |
6 | Replace the CH83 Main-B Circuit Board. Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |