0012CA (1st / 2nd Release Motor Overload Error)

Error contents
  • Overcurrent to the 1st / 2nd Release Motor was detected.
  • The 1st / 2nd Release Motor rotation speed is not attained or is not detected correctly.
Suspected cause
  • Abnormal load
  • 1st / 2nd Release Motor Encoder cable abnormality (connection, broken)
  • 1st / 2nd Release Motor cable abnormality (connection, broken)
  • 1st / 2nd Release Motor Encoder failure
  • 1st / 2nd Release Motor failure
  • CH83 Main-B Circuit Board failure
Parts/Components to be checked
  1. 1st/2nd Release Motor
  2. CH83 Main-B Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the obstacle in the PF operation range

  • Check if any obstacle is blocking the PF movement. If so, remove the obstacle.

Does the product recover from the error?

---EndGo to step 2
2

Check the 1st / 2nd Release Motor Encoder cable connection

  • Check the connection status of the 1st / 2nd Release Motor Encoder, and, if abnormal, reconnect.

Does the product recover from the error?

1st/2nd Release MotorEndGo to step 3
3

Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.

  • 1st / 2nd Release Motor Encoder (No.30) to CH83 Main-B Circuit Board (CN62)
  • 1st / 2nd Release Motor (No.4) to CH83 Main-B Circuit Board (CN62)

Does the product recover from the error?

1st/2nd Release Motor

CH83 Main-B Circuit Board

EndGo to step 4
4

Check the driving section of the 1st / 2nd Release Motor for foreign objects.

Does the product recover from the error?

1st/2nd Release MotorEndGo to step 5
5

Replace the 1st / 2nd Release Motor.

Does the product recover from the error?

1st/2nd Release MotorEndGo to step 6
6

Replace the CH83 Main-B Circuit Board.

Does the product recover from the error?

CH83 Main-B Circuit BoardEndEscalate to person in charge