Harness/FFC

Cable No.*ConnectionError code that occurs when the cable disconnection/connection failure
1CH83 Main-B Board - CH83 DRV-H Board FFC
  • CH83 Main-B Circuit Board (A) (CN21, CN200, CN20, CN22)
  • CH83 DRV-H Board (CN1, CN2, CN3, CN4)
  1. The LCD panel freezes on the "EPSON" screen
  2. The color of head 1 or head 2 comes out completely
  3. A large number of nozzles of either head 1 or head 2 are clogged, the nozzles are still clogging after cleaning.
  4. Printing (ink injection) stops during print operation.
  5. The printer prints abnormally.
2SUB PF Encoder Sensor HarnessCH83 Main-B Circuit Board (A) (CN73)
3PF Encoder Sensor HarnessCH83 Main-B Circuit Board (A) (CN72)
4Maintenance Box Cover SensorRelay cable (Printer Main Circuit Board (B) (CN90))
  • Maintenance box cover open error
  • No error occurs when opening and closing

Note "*": Underline: FFC