00124E (Sub PF Driven Roller Motor Velocity Deviation Error)

Error contents
  • The motor was detected to be driven at a speed abnormally faster than a predetermined one during acceleration or deceleration.
Suspected cause
  • Abnormal load
  • Sub PF Driven Roller Motor Encoder failure
  • Sub PF Driven Roller Motor failure
  • CH83 Main-B Circuit Board failure
Parts/Components to be checked
  1. Sub PF Encoder
  2. Sub PF Driven Roller Motor
  3. CH83 Main-B Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Replace the Sub PF Encoder

Does the product recover from the error?

Sub PF EncoderEndGo to step 2
2

Replace the Sub PF Driven Roller Motor

Does the product recover from the error?

Sub PF Driven Roller MotorEndGo to step 3
3

Replace the CH83 Main-B Circuit Board.

Does the product recover from the error?

CH83 Main-B Circuit BoardEndEscalate to person in charge