001138 (CR Motor Overcurrent Error)
Error contents
- There is an abnormality in the CR Motor or CR Encoder connection.
- The number of times of the detection of overcurrent flowing to the CR Motor has reached the specified value.
- CR Overload is abnormally high.
Suspected cause
- CR Motor failure
- Break (short) in the moving section of the CR Encoder Sensor FFC within the Head FFC Unit
- CR Belt state abnormality (tension, installation position)
- CR Motor cable abnormality (connection, broken)
- Incorrect reading of the CR Scale (scratch, contamination)
Parts/Components to be checked
- CR Motor
- Head FFC Assy
- CR Unit
- CR Scale
- CR Encoder
- CH83 SUB (PW/IMS) Board
- CH83 DRV-H Board
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check for abnormalities in CR operation
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the operation state of the CR Motor
Does the product recover from the error? | CR Motor | End | Go to step 3 |
3 | Check the Head FFC connection state
Does the product recover from the error? | Head FFC Assy | End | Go to step 4 |
4 | Check the CR Belt state
Does the product recover from the error? | End | Go to step 5 | |
5 | Check the cable connection of the CR Motor
Does the product recover from the error? | End | Go to step 6 | |
6 | Check the CR Scale state
Does the product recover from the error? | CR Scale | End | Go to step 7 |
7 | Replace the CR Encoder Does the product recover from the error? | CR Encoder | End | Go to step 8 |
8 | Replace the CH83 SUB (PW/IMS) Board Does the product recover from the error? | CH83 SUB (PW/IMS) Board | End | Go to step 9 |
9 | Replace the CH83 DRV-H Board Does the product recover from the error? | CH83 DRV-H Board | End | Go to step 10 |
10 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |