018702 (Scanner Paper Feed Flap Opening / Closing Motor Reversing Error)
Error contents
- The number of occurrences of reversing the Scanner Paper Feed Flap Opening / Closing Motor has reached a predetermined limit.
Suspected cause
- Paper jam
- Scanner Paper Feed Flap Opening / Closing Scale Encoder cable abnormality (polarity reversal)
- Scanner Paper Feed Flap Opening / Closing Motor cable abnormality (polarity reversal)
- Scanner Paper Feed Flap Motor Assy and Flap Gears erroneous connection
- Slipping of the teeth of the Scanner Paper Feed Flap Opening / Closing gears
- Scanner Paper Feed Flap Scale Encoder failure
Parts/Components to be checked
- Flap Gears
- Document Motor Scale Encoder
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check for paper jam
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the Scanner Paper Feed Flap Opening / Closing Encoder cable connection
Does the product recover from the error? | --- | End | Go to step 3 |
3 | Check the Scanner Paper Feed Flap Opening / Closing Motor cable connection
Does the product recover from the error? | --- | End | Go to step 4 |
4 | Checking the Scanner Paper Feed Flap Opening / Closing Scale / Encoder state
Does the product recover from the error? | --- | End | Go to step 5 |
5 | Check the state of the Flap Gears
Does the product recover from the error? | End | Escalate to person in charge |
Checking the Scanner Paper Feed Flap Opening / Closing Scale / Encoder state