00141A (Pump Cap Unit Overload Error)
Error contents
- The Pump Motor did not operate normally due to some load and an overcurrent higher than the specified value was detected.
Suspected cause
- Pump Motor Encoder cable abnormality (connection, broken)
- Pump Motor cable abnormality (connection, broken)
- Abnormal load
- Pump Motor Encoder failure
- Pump Motor failure
Parts/Components to be checked
- Pump Cap unit
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Execute power OFF/ON (the cycle may be corrected by power OFF/ON). Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the obstacle in the Pump Cap Unit operation range.
Does the product recover from the error? | Pump Cap unit | End | Go to step 3 |
3 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 4 | |
4 | Check the Pump Cap Unit operation state.
Does the product recover from the error? | Pump Cap unit | End | Go to step 5 |
5 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |