0186A3 (Document Feed Motor Lock Error)
Error contents
- The Document Feed Motor does not operate, and a certain period of time has passed. (Detected that this does not operate at the timing for operation.)
Suspected cause
- Document Feed Scale Encoder cable abnormality (connection, broken)
- Document Feed Motor cable abnormality (connection, broken)
- Abnormal load (paper jam, foreign object)
- Document Feed Scale Encoder failure
- Document Feed Motor failure
- Document Feed Gears failure
Parts/Components to be checked
- Document Feed Scale Encoder
- Document Feed Motor
- Document Feed Gears
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check for paper jam and foreign objects
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the Document Feed Scale Encoder cable connection
Does the product recover from the error? | --- | End | Go to step 3 |
3 | Check the Document Feed Motor cable connection
Does the product recover from the error? | --- | End | Go to step 4 |
4 | Checking the Document Feed Gears state
Does the product recover from the error? | --- | End | Go to step 5 |
5 | Replace the Document Feed Scale Encoder Does the product recover from the error? | End | Go to step 6 | |
6 | Replace the Document Feed Motor Does the product recover from the error? | Document Feed Motor | End | Escalate to person in charge |