0012CF (1st / 2nd Release Motor Lock Error)
Error contents
- The 1st / 2nd Release Motor was driven at a speed abnormally slower than a predetermined one during operation.
- The waveform is not detected when the 1st / 2nd Release Motor is driving.
Suspected cause
- 1st / 2nd Release Motor Encoder cable abnormality (connection, broken)
- 1st / 2nd Release Motor cable abnormality (connection, broken)
- Abnormal load
- 1st / 2nd Release Motor Encoder failure
- 1st / 2nd Release Motor failure
Parts/Components to be checked
- 1st/2nd Release Motor
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the 1st / 2nd Release Motor Encoder cable connection
Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 2 |
2 | Check the 1st / 2nd Release Motor cable connection
Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 3 |
3 | Replace the 1st / 2nd Release Motor Does the product recover from the error? | 1st/2nd Release Motor | End | Escalate to person in charge |