00130F (ASF Motor Lock Error)
Error contents
- The ASF Motor was driven at a speed abnormally slower than a predetermined one during operation.
- The waveform is not detected when the ASF Motor is driving.
Suspected cause
- ASF Motor Encoder cable abnormality (connection, broken)
- ASF Motor cable abnormality (connection, broken)
- Abnormal load
- ASF Motor Encoder failure
- ASF Motor failure
Parts/Components to be checked
- ASF Motor
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 2 | |
2 | Replace the ASF Motor Does the product recover from the error? | ASF Motor | End | Escalate to person in charge |