001549 (Cutter Motor Oscillation Error)

Error contents
  • The number of oscillations exceeds the specified value.
  • The control terminal (Vre terminal) of the Cutter Motor Driver was short-circuited.
Suspected cause
  • Printer Main Circuit Board failure

  • Cutter Motor failure
Parts/Components to be checked
  1. Printer Main Circuit Board
  2. Cutter Motor Unit
  3. Cutter Rail Unit
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the Printer Main Circuit Board state

  • Check if any foreign object is on the Printer Main Circuit Board. If a foreign object is found, remove it.

Does the product recover from the error?

Printer Main Circuit BoardEndGo to step 2
2

Replace the Printer Main Circuit Board.

Does the product recover from the error?

Printer Main Circuit BoardEndGo to step 3
3

Replace the Cutter Motor Unit.

Does the product recover from the error?

Cutter Motor UnitEndGo to step 4
4

Replace the Cutter Rail Unit.

Does the product recover from the error?

Cutter Rail UnitEndEscalate to person in charge