001549 (Cutter Motor Oscillation Error)
Error contents
- The number of oscillations exceeds the specified value.
- The control terminal (Vre terminal) of the Cutter Motor Driver was short-circuited.
Suspected cause
Printer Main Circuit Board failure
- Cutter Motor failure
Parts/Components to be checked
- Printer Main Circuit Board
- Cutter Motor Unit
- Cutter Rail Unit
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the Printer Main Circuit Board state
Does the product recover from the error? | Printer Main Circuit Board | End | Go to step 2 |
2 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Go to step 3 |
3 | Replace the Cutter Motor Unit. Does the product recover from the error? | Cutter Motor Unit | End | Go to step 4 |
4 | Replace the Cutter Rail Unit. Does the product recover from the error? | Cutter Rail Unit | End | Escalate to person in charge |