00151C (APG Motor Driving time-out Error)
Error contents
- The number of occurrences of reversing the APG Motor has reached a predetermined limit.
Suspected cause
- APG Motor Encoder cable abnormality (polarity reversal)
- APG Motor cable abnormality (polarity reversal)
- Slipping of the teeth of the APG Motor Gears
- APG Motor Encoder failure
Parts/Components to be checked
- APG Unit
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check state of gears within the APG unit.
Does the product recover from the error? | APG Unit | End | Go to step 2 |
2 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 3 | |
3 | Replace the APG Unit. Does the product recover from the error? | APG Unit | End | Escalate to person in charge |