00167F (Cooling Fan Lock Error)

Error contents
  • Drive is instructed to the Power Unit Cooling Fan (CN602) from the Main Circuit Board but the fan does not drive.
Suspected cause
  • Cable connector abnormality of the Power Unit Cooling Fan (disconnection/inserted halfway/skewed connection)
  • Power Unit Cooling Fan failure

  • Printer Main Circuit Board failure
  • CN602 cable broken (relay cable from cable of Power Unit Cooling Fan side/up to board/from board to board)
Parts/Components to be checked
  1. PSL Cooling Fan Unit
  2. Printer Main Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the cable connection of the PSL Cooling Fan Unit

  • Check the PSL Cooling Fan Unit cable connection status again, and reconnect if abnormal.

Does the product recover from the error?

PSL Cooling Fan UnitEndGo to step 2
2

Replace the PSL Cooling Fan Unit

Does the product recover from the error?

PSL Cooling Fan UnitEndGo to step 3
3

Replace the Printer Main Circuit Board.

Does the product recover from the error?

Printer Main Circuit BoardEndEscalate to person in charge