001B00 (I2C Communication Time-out Error)
Error contents
- There is no response from the Panel Unit.
- No response from the CH83 SUB (On-CR) Board.
Suspected cause
- Panel Board failure
- Replace the CH83 SUB (PW/IMS) Board
- Panel FFC abnormality (skewed connection/broken lead/short-circuit)
- PW/IMS Harness abnormality (skewed connection/broken lead/short-circuit)
Parts/Components to be checked
- Panel FFC Assy
- Head FFC Assy
- Panel Assy
- CH83 SUB (PW/IMS) Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Turn power OFF/ON Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the connection status of the Panel FFC/PW/IMS FFC
Does the product recover from the error? | End | Go to step 3 | |
3 | Replace the Panel Assy Does the product recover from the error? | Panel Assy | End | Go to step 4 |
4 | Replace the CH83 SUB (PW/IMS) Board Does the product recover from the error? | CH83 SUB (PW/IMS) Board | End | Escalate to person in charge |