The inside light is not on (print side)
Suspected cause
LED cable connection abnormality (coming off)
LED short-circuit
Parts/Components to be checked
CE46 SUB-R Board Home
CE46 SUB-R Board Full
Troubleshooting
| Step | Confirmation points and methods | Page | YES | NO |
|---|---|---|---|---|
| 1 | Check the CE46 SUB-R Board Home/CE46 SUB-R Board Full cable connection.
Does the product recover from the failure? | End | Go to step 2 | |
| 2 | Replace the CE46 SUB-R Board Home/CE46 SUB-R Board Full Does the product recover from the failure? | End | Escalate to person in charge |