0016CA (Shutter Motor Overload Error)

Error contents
  • Overcurrent is detected more than predetermined limit since the Shutter Motor did not operate properly because of some kind of load.
Suspected cause
  • Shutter Motor Encoder cable abnormality (connection, broken)
  • Shutter Motor cable abnormality (connection, broken)
  • Abnormal load
  • Shutter Motor Encoder failure
  • Shutter Motor failure
Parts/Components to be checked
  1. Shutter Motor Unit
  2. CH83 Main-B Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the cable connection of the Shutter Motor Unit

  • Check the connection status of the Shutter Motor Unit and, if abnormal, reconnect.

Does the product recover from the error?

Shutter Motor Unit

CH83 Main-B Circuit Board

EndGo to step 2
2

Replace the shutter Motor Unit.

Does the product recover from the error?

Shutter Motor UnitEndEscalate to person in charge