0016CA (Shutter Motor Overload Error)
Error contents
- Overcurrent is detected more than predetermined limit since the Shutter Motor did not operate properly because of some kind of load.
Suspected cause
- Shutter Motor Encoder cable abnormality (connection, broken)
- Shutter Motor cable abnormality (connection, broken)
- Abnormal load
- Shutter Motor Encoder failure
- Shutter Motor failure
Parts/Components to be checked
- Shutter Motor Unit
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the cable connection of the Shutter Motor Unit
Does the product recover from the error? | End | Go to step 2 | |
2 | Replace the shutter Motor Unit. Does the product recover from the error? | Shutter Motor Unit | End | Escalate to person in charge |