00112C (Intermediate Sub PF Driven Home Position Detection Error)
Error contents
- The sub driven nip home position cannot be detected at the time of initialization.
- The sub driven nip cannot return or the sensor does not react.
Suspected cause
- The Mechanical Sensor has failed or its position has been shifted.
- Operation failure due to paper jam
- Poor connection of the Sub Driven Release Home Position Sensor
- Sub Driven Release Home Position Sensor failure
- Sub Driven Release Motor failure
- Slipping of the teeth of the Sub Driven Nip Gears
- Sub PF driven shaft screw is loosen, and a sensor read position abnormality occurs.
- A: Normal read position
- B: Read position when error occurs
<Normal read position>
- A: Sub PF driven home position flag
- B: Sub PF driven shaft
- C: Screw
- D: Sensor
- E: Sensor detection range
<Read position when error occurs>
- A: Error occurs due to moving the flag
Parts/Components to be checked
- Sub PF Driven Sensor
- 1st/2nd Release Motor
- ASF sub Gears
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check around the Sub Driven Nip for paper jams. Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the cable connection of the Sub PF Driven Sensor
Does the product recover from the error? | End | Go to step 3 | |
3 | If shaft screw is loose, tighten it again.
Does the product recover from the error? | --- | End | Go to step 4 |
4 | Replace the 1st / 2nd Release Motor Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 5 |
5 | Replace the ASF Sub Gears Does the product recover from the error? | ASF sub Gears | End | Escalate to person in charge |