0014C3 (Flushing Box Lid Open/Close Error)
Error contents
- Flushing Box lid open/close operational abnormality detected.
Suspected cause
- Flushing Box lid open/close operation not possible.
- With the Flushing Box lid on, ink suction operation started.
- Lid open/close operation is reversed. (Position skewed, and with the Flushing Box lid on, ink suction operation started.)
Parts/Components to be checked
- Pump Cap unit
- Cap Unit
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Backup parameters, and escalate to the person in charge. | Service Program Basic Operations | - | - |
2 | Clean the lip part (seal surface) of the Cap Unit. Does the product recover from the error? | Cap Unit | End | Go to step 3 |
3 | Replace the Pump Cap Unit Does the product recover from the error? | Pump Cap unit | End | Go to step 4 |
4 | Replace the Cap Unit Does the product recover from the error? | Cap Unit | End | Go to step 5 |
5 | Perform Line CL1 for all rows. Does the product recover from the error? | Cleaning | End | Go to step 6 |
6 | Perform the Pump Cap Unit Measurement & Auto Adjustment. Does the product recover from the error? | Pump Cap Unit Measurement & Auto Adjustment | End | Escalate to person in charge |