0014C3 (Flushing Box Lid Open/Close Error)

Error contents
  • Flushing Box lid open/close operational abnormality detected.
Suspected cause
  • Flushing Box lid open/close operation not possible.
  • With the Flushing Box lid on, ink suction operation started.
  • Lid open/close operation is reversed. (Position skewed, and with the Flushing Box lid on, ink suction operation started.)
Parts/Components to be checked
  1. Pump Cap unit
  2. Cap Unit
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Backup parameters, and escalate to the person in charge.

Service Program Basic Operations
2

Clean the lip part (seal surface) of the Cap Unit.

Does the product recover from the error?

Cap UnitEndGo to step 3
3

Replace the Pump Cap Unit

Does the product recover from the error?

Pump Cap unitEndGo to step 4
4

Replace the Cap Unit

Does the product recover from the error?

Cap UnitEndGo to step 5
5

Perform Line CL1 for all rows.

Does the product recover from the error?

CleaningEndGo to step 6
6

Perform the Pump Cap Unit Measurement & Auto Adjustment.

Does the product recover from the error?

Pump Cap Unit Measurement & Auto AdjustmentEndEscalate to person in charge