Scanner (2)
Cable No.* | Connection | Error code that occurs when the cable disconnection/connection failure | |
---|---|---|---|
1 | CIS Module Full Side (A) | CIS Module Full Side Board (B) | Part or all of an image cannot be read. |
2 | CIS Module Full Side Board (E) | Scanner Main Board (C) (CN46, CN47) | |
3 | CIS Module Center Board (H) | Scanner Main Board (C) (CN43, CN44) | |
4 | CIS Module Home Side Board (F) | Scanner Main Board (C) (CN39, CN40) | |
5 | CIS Module Home Side (E) | CIS Module Home Side Board (F) | Part or all of an image cannot be read. |
6 | CIS Module Center (G) | CIS Module Center Board (H) | Part or all of an image cannot be read. |
Note "*": Underline: FFC