00124F (Sub PF Driven Roller Motor Lock Error)
Error contents
- The Sub PF Driven Roller Motor was detected to be driving at an abnormal speed lower than the specified speed when driving.
- The waveform is not detected when the Sub PF Driven Roller Motor is driving.
Suspected cause
- Sub PF Driven Roller Motor Encoder cable abnormality (connection, broken)
- Sub PF Driven Roller Motor cable abnormality (connection, broken)
- Abnormal load
- Sub PF Driven Roller Motor Encoder failure
- Sub PF Driven Roller Motor failure
Parts/Components to be checked
- Sub PF Encoder
- Sub PF Driven Roller Motor
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the Sub PF Encoder cable connection.
Does the product recover from the error? | Sub PF Encoder | End | Go to step 2 |
2 | Check the cable connection of the Sub PF Driven Roller Motor
Does the product recover from the error? | Sub PF Driven Roller Motor | End | Go to step 3 |
3 | Replace the Sub PF Encoder Does the product recover from the error? | Sub PF Encoder | End | Go to step 4 |
4 | Replace the Sub PF Driven Roller Motor Does the product recover from the error? | Sub PF Driven Roller Motor | End | Escalate to person in charge |