018705 (Scanner Paper Feed Flap Opening / Closing Motor Overload Error)
Error contents
- Abnormal value more than predetermined limit is detected since the Scanner Paper Feed Flap Opening / Closing Motor did not operate properly because of some kind of load.
Suspected cause
- Abnormal load (paper jam, foreign object)
- Scanner Paper Feed Flap Opening / Closing Scale Encoder cable abnormality (connection, broken)
- Scanner Paper Feed Flap Opening / Closing Motor cable abnormality (connection, broken)
- Scanner Paper Feed Flap Scale Encoder failure
- Scanner Paper Slot Motor failure
- Scanner Paper Feed Flap Opening / Closing gears failure
Parts/Components to be checked
- Scanner Paper Feed Flap Motor Assy
- Flap Gears
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check for paper jam and foreign objects
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the Scanner Paper Feed Flap Opening / Closing Encoder cable connection
Does the product recover from the error? | --- | End | Go to step 3 |
3 | Check the Scanner Paper Feed Flap Opening / Closing Motor cable connection
Does the product recover from the error? | --- | End | Go to step 4 |
4 | Check the state of the Flap Gears
Does the product recover from the error? | End | Escalate to person in charge |