256226/356226/DBA2 (CH83 Main-B Circuit Board Watchdog Error Occurred)
Error contents
- CH83 Main-B Circuit Board watchdog error occurred.
Suspected cause
- CH83 Main-B Circuit Board failure (SOC not operating)
Parts/Components to be checked
- CH83 Main-B Circuit Board
- CH83 Main Board - CH83 Main-B Board FFC
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Turn power OFF/ON Does the product recover from the error? | --- | End | Go to step 2 |
2 | Replace the CH83 Main-B Circuit Board Does the product recover from the error? | CH83 Main-B Circuit Board | End | Go to step 3 |
3 | Check the connection status of the FFC/cable between the Printer Main Circuit Board and CH83 Main-B Circuit Board