00141D (Pump Cap Unit Driving time-out Error)
Error contents
- Abnormally-long driving duration of the Pump Motor was detected.
Suspected cause
- As a result of damage to a part inside the Pump Cap due to an abnormal load or sensor abnormality, the specified signals are not received within the specified period (unable to detect).
- Firmware becomes out of control
Parts/Components to be checked
- Firmware
- Printer Main Circuit Board
Troubleshooting
| Step | Confirmation points and methods | Page | YES | NO |
|---|---|---|---|---|
| 1 | Firmware Update Does the product recover from the error? | Firmware Install | End | Go to step 2 |
| 2 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |