001FB9 (CS Rank Outside Setting Range Error)
Error contents
- Printer Main Circuit Board internal parameters have an abnormal value.
Suspected cause
- Printer Main Circuit Board failure
Parts/Components to be checked
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Escalate to person in charge |