001519 (APG Motor Oscillation Error)
Error contents
- The number of oscillations exceeds the specified value.
- The control terminal (Vre terminal) of the AGP Motor Driver was short-circuited.
Suspected cause
- Printer Main Circuit Board failure
- APG Unit failure
Parts/Components to be checked
- Printer Main Circuit Board
- APG Unit
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the Printer Main Circuit Board state
Does the product recover from the error? | Printer Main Circuit Board | End | Go to step 2 |
2 | Replace the Printer Main Circuit Board. Does the product recover from the error? | Printer Main Circuit Board | End | Go to step 3 |
3 | Replace the APG Unit. Does the product recover from the error? | APG Unit | End | Escalate to person in charge |