00122F (PF Driven Roller Motor Lock Error)
Error contents
- The PF Driven Roller Motor was detected to be driving at an abnormal speed lower than the specified speed when driving.
- The waveform is not detected when the PF Driven Roller Motor is driving.
Suspected cause
- PF Driven Roller Motor Encoder cable abnormality (connection, broken)
- PF Driven Roller Motor cable abnormality (connection, broken)
- Abnormal load
- PF Driven Roller Motor Encoder failure
- PF Driven Roller Motor failure
Parts/Components to be checked
- PF Encoder
- PF Driven Roller Motor
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the PF Encoder cable connection.
Does the product recover from the error? | PF Encoder | End | Go to step 2 |
2 | Check the cable connection of the PF Driven Roller Motor
Does the product recover from the error? | PF Driven Roller Motor | End | Go to step 3 |
3 | Replace the PF Encoder Does the product recover from the error? | PF Encoder | End | Go to step 4 |
4 | Replace the PF Driven Roller Motor Does the product recover from the error? | PF Driven Roller Motor | End | Escalate to person in charge |