0012CE (1st / 2nd Release Motor Velocity Deviation Error)

Error contents
  • The motor was detected to be driven at a speed abnormally faster than a predetermined one during acceleration or deceleration.
Suspected cause
  • Abnormal load
  • 1st / 2nd Release Motor Encoder failure
  • 1st / 2nd Release Motor failure
  • Printer Main Circuit Board failure

  • CH83 Main-B Circuit Board failure
Parts/Components to be checked
  1. 1st/2nd Release Motor
  2. CH83 Main-B Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Replace the 1st / 2nd Release Motor

Does the product recover from the error?

1st/2nd Release MotorEndGo to step 2
2

Replace the CH83 Main-B Circuit Board.

Does the product recover from the error?

CH83 Main-B Circuit BoardEndEscalate to person in charge