0012CE (1st / 2nd Release Motor Velocity Deviation Error)
Error contents
- The motor was detected to be driven at a speed abnormally faster than a predetermined one during acceleration or deceleration.
Suspected cause
- Abnormal load
- 1st / 2nd Release Motor Encoder failure
- 1st / 2nd Release Motor failure
Printer Main Circuit Board failure
- CH83 Main-B Circuit Board failure
Parts/Components to be checked
- 1st/2nd Release Motor
- CH83 Main-B Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Replace the 1st / 2nd Release Motor Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 2 |
2 | Replace the CH83 Main-B Circuit Board. Does the product recover from the error? | CH83 Main-B Circuit Board | End | Escalate to person in charge |