202620/302620/0A3C (Wireless Board Failure Occurred)

Error contents
  • A wireless board failure occurred.
Suspected cause
  • Harness disconnected (WLAN Board/CH83 IF Board/Printer Main Circuit Board)
  • WLAN Board failure
Parts/Components to be checked
  1. CH83 Sub IF Board
  2. Wireless LAN (WLAN) Board
  3. Printer Main Circuit Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Check the connection status of the harness (WLAN Board/CH83 IF Board/Printer Main Circuit Board)

  • Check the connection status (disconnection, skewed connection, inserted halfway, peeled terminal) of the harness (WLAN Board/CH83 IF Board/Printer Main Circuit Board). If an abnormality is found, reconnect it.

Does the product recover from the error?

EndGo to step 2
2

Replace the Wireless LAN (WLAN) Board

Does the product recover from the error?

Wireless LAN (WLAN) BoardEndEscalate to person in charge