00130C (ASF Motor Driving time-out Error)
Error contents
- The number of occurrences of reversing the ASF Motor has reached a predetermined limit.
Suspected cause
- ASF Motor Encoder cable abnormality (polarity reversal)
- ASF Motor cable abnormality (polarity reversal)
- ASF Gears slipping
- ASF Motor Encoder failure
Parts/Components to be checked
- ASF Gears
- ASF Motor
- Printer Main Circuit Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the state of the ASF Gears
Does the product recover from the error? | ASF Gears | End | Go to step 2 |
2 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 3 | |
3 | Replace the ASF Motor. Does the product recover from the error? | ASF Motor | End | Escalate to person in charge |