0012CC (1st / 2nd Release Motor Reversing Error)
Error contents
- The number of occurrences of reversing the 1st / 2nd Release Motor has reached a predetermined limit.
Suspected cause
- 1st / 2nd Release Motor Encoder cable abnormality (polarity reversal)
1st / 2nd Release Motor cable abnormality (polarity reversal)
- 1st / 2nd Release Motor gear slipping
- 1st / 2nd Release Motor Encoder failure
Parts/Components to be checked
- 1st/2nd Release Motor
- CH83 Main-B Circuit Board
Troubleshooting
| Step | Confirmation points and methods | Page | YES | NO |
|---|---|---|---|---|
| 1 | Check the state of the 1st / 2nd Release Motor gear.
Does the product recover from the error? | 1st/2nd Release Motor | End | Go to step 2 |
| 2 | Check the following connections for an abnormality such as a connector disconnection or a broken cable. If an abnormality is found, reconnect it.
Does the product recover from the error? | End | Go to step 3 | |
| 3 | Replace the 1st / 2nd Release Motor. Does the product recover from the error? | 1st/2nd Release Motor | End | Escalate to person in charge |