001A24 (Head Outbound Acceleration FL Timeout Error)
Error contents
- The flushing process does not end at the time of implementation of interval flushing. (The process does not end even after 20 seconds or more have elapsed.)
- The drive waveform program of the head does not detect an end.
Suspected cause
- FW failure (specifications problem)
- Due to contamination of the CR Encoder or CR Scale, the correct position of the carriage could not be read, and the carriage operation stopped for 20 seconds or more.
- The CH83 DRV-H Board has failed (a location for which waveform control is performed has failed)
Parts/Components to be checked
- CR Encoder
- CR Scale
- CH83 DRV-H Board
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Turn power OFF/ON Does the product recover from the error? | --- | End | Go to step 2 |
2 | Clean the CR Encoder/CR Scale. If the condition does not improve after cleaning, replace the CR Encoder/CR Scale. Does the product recover from the error? | End | Go to step 3 | |
3 | Reinstall the FW Does the product recover from the error? | Firmware Install | End | Go to step 4 |
4 | Replace the CH83 DRV-H Board Does the product recover from the error? | CH83 DRV-H Board | End | Escalate to person in charge |