001A24 (Head Outbound Acceleration FL Timeout Error)

Error contents
  • The flushing process does not end at the time of implementation of interval flushing.  (The process does not end even after 20 seconds or more have elapsed.)
  • The drive waveform program of the head does not detect an end.
Suspected cause
  • FW failure (specifications problem)
  • Due to contamination of the CR Encoder or CR Scale, the correct position of the carriage could not be read, and the carriage operation stopped for 20 seconds or more.
  • The CH83 DRV-H Board has failed (a location for which waveform control is performed has failed)
Parts/Components to be checked
  1. CR Encoder
  2. CR Scale
  3. CH83 DRV-H Board
Troubleshooting
StepConfirmation points and methodsPageYESNO
1

Turn power OFF/ON

Does the product recover from the error?

---EndGo to step 2
2

Clean the CR Encoder/CR Scale.

If the condition does not improve after cleaning, replace the CR Encoder/CR Scale.

Does the product recover from the error?

CR Encoder

CR Scale

EndGo to step 3
3

Reinstall the FW

Does the product recover from the error?

Firmware InstallEndGo to step 4
4

Replace the CH83 DRV-H Board

Does the product recover from the error?

CH83 DRV-H BoardEndEscalate to person in charge