001A42 (Head Temperature Error (Head))
Error contents
- Head internal thermistor temperature abnormality
Abnormal heat generation detected within the Print Head
Suspected cause
- Print Head failure
- Drive waveform abnormality
- Head Thermistor abnormality (Printhead failure)
Parts/Components to be checked
- Head FFC Assy
- Print Head
Troubleshooting
| Step | Confirmation points and methods | Page | YES | NO |
|---|---|---|---|---|
| 1 | Turn power OFF/ON Does the product recover from the error? | --- | End | Go to step 2 |
| 2 | Check the Head FFC connection state
Does the product recover from the error? | Head FFC Assy | End | Go to step 3 |
| 3 | Replace the Print Head Does the product recover from the error? | Print Head | End | Escalate to person in charge |