00113A (CR Motor Overload Error)
Error contents
- The CR Motor did not operate normally due to some load and an overcurrent higher than the specified value was detected.
- The CR Motor rotation speed is not attained or is not detected correctly.
Suspected cause
- A paper jam has occurred.
- CR Encoder cable abnormality (connection, broken)
- CR Motor cable abnormality (connection, broken)
- CR Motor abnormal load
- CR Encoder failure
- CR Motor failure
Parts/Components to be checked
- CR Unit
- CR Encoder
- CR Motor
- CH83 SUB (PW/IMS) Board
- CH83 Main-B Circuit Board
- CR Slider (Home)
- CR Slider (Full)
Troubleshooting
Step | Confirmation points and methods | Page | YES | NO |
---|---|---|---|---|
1 | Check the obstacle in the CR moving range.
Does the product recover from the error? | --- | End | Go to step 2 |
2 | Check the CR Unit state.
Does the product recover from the error? | End | Go to step 3 | |
3 | Check the cable connection of the CR Motor
Does the product recover from the error? | End | Go to step 4 | |
4 | Check the reading state of the CR Encoder. If reading (from the Service Program) cannot be performed, re-install the CR Encoder. Does the product recover from the error? | End | Go to step 5 | |
5 | Lubrication to the oil pad within the CR Slider. Does the product recover from the error? | Lubrication 10 | End | Go to step 6 |
6 | Replace the CR Slider. Does the product recover from the error? | End | Go to step 7 | |
7 | Replace the CR Encoder. Does the product recover from the error? | CR Encoder | End | Go to step 8 |
8 | Replace the CR Motor. Does the product recover from the error? | CR Motor | End | Go to step 9 |
9 | Replace the CR Unit. Does the product recover from the error? | CR Unit | End | Escalate to person in charge |